up

HOME SERVICE SITE MAP CONTACT US
Sterilization as expected. Color touch panel
New standard machine for autoclaving
HICLAVE
HV-Ⅱseries
HV-25Ⅱ / HV-50Ⅱ
HV-85Ⅱ / HV-110Ⅱ
  • Color touch panel
  • Electro-mechanical lid lock system
  • Memory function
  • Dual interlock mechanism
  • Lid lock release temperature setting
  • Air removal time setting
  • Forced cooling unit(option)

  •  ■ Features & Functions
    Color touch panel
    A color touch panel allows an operator to understand the operation screen contents at a glance.

    Electro-mechanical lid lock system
    The lid can be opened and closed easily and reliably with the one-touch lever. A pressure seal method is used as a safety measure.
    Dual interlock mechanism
    The lid is locked by dually detecting the chamber pressure and chamber temperature during operation. The lock state is maintained even if an operation is manually interrupted.
    Memory function
    Up to 8 patterns for each mode can be registered according to the purpose of use.
    The lid lock release temperature setting
    The lid lock release temperature can be set up for each mode or program to secure safety at the time of unloading.               
    Air removal time setting
    It is effective for sterilization of Durham tubes etc. from which air is difficult to escape.                
    Dual detection system for residual air
    The residual air which may cause sterilization failure is dually detected to always maintain the appropriate sterilization conditions for loads.
    ※Detection of residual air is performed dually when the chamber pressure is normal (during air removal by gravity displacement) and when the chamber is pressurized (during air removal by pressure exhaust).
     
    Forced cooling unit (option)
    After sterilization, the chamber pressure is lowered by cooling with a forced cooling unit (air-cool) to shorten the time to unloading.                
    Programmable auto-start function
    It is a timer function that starts an operation at the set time.
    ※The operation start time can be set up to 1 week later.                
    Required utilities    
    Power supply: Refer to the specifications. Household outlets are not recommended.

    ※Ask us for details.
     ■ Easy to use with color touch panel
    A color touch panel allows an operator to understand the operation screen contents at a glance.

    Confirmation items are notified
    at startup.
    A mode can be selected simply
    by touching the screen.
    When the power is turned on, the confirmation items
    before use are displayed. You can reduce the trouble by
    implementing the confirmation items.
    A mode can be selected with the simple operation of tou-
    ching the desired mode from 5 modes displayed on the
    color touch panel and pressing the start button.

    Color display makes it easier to understand various settings.
    The settings of temperature, time, warming and exhaust can be easily changed by touch operation while checking the color screen.The set contents can be registered up to 8 patterns. It is very convenient when sharing and using with a plurality of names.

    Sterilization temperature setting

    Registration and selection of memory

    Security & Safety
    Various information such as settings, safety and warnings are displayed on a color screen.
    More detailed contents are shown by text information.

    [  Alarms  ]
    11 kinds of alarms such as a low water heating alarm are
    displayed.

    [  Alarm history  ]
    Alarm occurrence date, alarm contents and stage ID number
    are displayed.


    [  System information  ]
    Progrm version number, cycle count, next self inspection
    date are displayed.
     ■ Operation cycle of each mode (Up to 8 patterns for each mode can be registered.)
                  LIQUID modeHeatingSterilizationVariable exhaust
      ●Main applications: Sterilization of liquid, which can withstand high temperature and high pressure steam such as water, culture medium, reagent, reagent solution, liquid medicine, etc.
     
                  SOLID modeHeatingSterilizationForced exhaust
      ●Main applications: Sterilization of instruments made of glass, ceramic, metal or rubber that can withstand high temperature, high pressure steam and rapid pressure decrease during the exhaust stage.
     
                  WASTE modeHeatingSterilizationForced exhaust
      ●Main applications: Sterilization of waste using a sterilization bag and the like.
                  AGAR modeHeatingSterilizationVariable exhaustWarming
      ●Main applications: Sterilization of agar medium (It is warmed at constant temperature to prevent clotting after sterilization.)
                 DISSOLUTION modeHeatingWarming
      ●Main applications: Dissolution of agar medium (It is warmed at constant temperature to prevent clotting after heating.)
     ■ Options for upgrading a system (retrofittable)
                                                                                                                                                                                                
    Forced cooling unit
    (air-cool)
    Floating sensorRecorderCore temperature sensor
    Used to shorten the time to unloading after sterilizationA sterilization timer operates after the temperature of the materials to be sterilzed reaches the set temperature.(Image is a chart type recorder.)
    ・Chart type recorder: 6-point dotting
    ・Hybrid recorder: 8-point dotting
    ※Chart width: 100 mm
    ※Class 2 T-type thermocouple included
    Class 2 T-type thermocouple Connection with recorder is required.
                                                                                                                  
    PrinterAutomatic water supply unit
    Thermal print typeManual water supply to the chamber becomes unnecessary.
     ■ Options
    Round wire mesh basket, stainless steel Sterilization bucket, stainless steel Round wire mesh basket with solid bottom, stainless steel
    [For HV-25Ⅱ]
    φ210 x H255 mm

    [For HV-50Ⅱ]
    φ270 x H220 mm
    φ270 x H270 mm

    [For HV-85Ⅱ]
    φ380 x H285 mm

    [For HV-110Ⅱ]
    φ380 x H375 mm
    [For HV-25Ⅱ]
    φ210 x H255 mm

    [For HV-50Ⅱ]
    φ270 x H220 mm
    φ270 x H270 mm

    [For HV-85Ⅱ・with holes / without holes]
    φ390 x H285 mm

    [For HV-110Ⅱ・with holes / without holes]
    φ390 x H375 mm

    It is recommended to use it when using a sterilization bag. A large capacity and bucket-shape bottom can prevent the chamber from being contaminated when a sterilization bag is broken.

    [For HV-25Ⅱ]
    φ210 x H420 mm

    [For HV-50Ⅱ]
    φ270 x H600 mm

    ※Use a sterilization bag without closing the mouth.
                                                          
    Detergent for autoclave Sterilization bagDeodorizer
    Detergent to remove culture media, water scale sticked to the inside of a chamber

    [Standard amount of use]
    1 cap of detergent in 2 L of water (20 ml・1%)

    ※Take out the materials at the time of use.

    500 ml
    Special structure reinforced film.
    Heat resistant temperature is 130℃

    [Type:A] 200 pcs
    500 x 700 mm
    [Type:B] 200 pcs
    620 x 820 mm

    ※Use it without closing the mouth.
    Deodorizer for the "unpleasant odor" generated during sterilization of culture media etc.

    It melts smoothly in the sterilization process and exerts a deodorization effect.

    Standard amount of deodorant according to the autoclave capacity
    less than 40 L: 2-3 T at once
    from 40 L to 60 L: 4 T at once
    from 60 L to 100 L: 6 T at once
    100 T / bottle
                                                   
    Sterilization tape, Sterilization label, Sterilization bag
    ■Sterilization tape: Clear color change makes it easy to identify exposure to sterilization process.
    ■Sterilization label: Paste directly on the object to be sterilized, you can check the sterilization treatment. After sterilization, the letters "sterilized" appear and it can be easily distinguished from untreated materials.
    ■Sterilization bag: There are sterilization bags that are made of paper, roll type or one seal back type. Most of them are heat seal type, but tape seal type and aluminum plate seal type can be also available.

    ※Ask us for prices and more details.
     ■ Specifications
    Product nameHICLAVE HV-Ⅱ series
    ModelHV-25ⅡHV-50ⅡHV-85ⅡHV-110Ⅱ
    Effective capacity25 L50 L85 L110 L
    Chamber size (φ x H mm)240 x 550300 x 710420 x 615420 x 795
    Operation mode5 modes (LIQUID, SOLID, WASTE, AGAR, DISSOLUTION) ※Settings can be registered in 8 memories.
    Temperature
    setting range
    Sterilization105℃ - 126℃ Variable105℃ - 135℃ Variable
    Dissolution60℃ - 100℃ Variable
    Warming45℃ - 60℃ Variable
    Lid lockLIQUID, AGAR, DISSOL modes: 60℃ - 95℃ Variable / SOLID, WASTE modes: 60℃ - 97℃ Variable
    Time setting rangeSterilization1 min - 250 min, Remaining time is displayed
    Dissolution1 min - 60 min, Remaining time is displayed
    Warming20 h, fixed
    Auto-startProgram autoclave to start 1 min to 1 week later
    Air removal3 min - 9 min Variable6 min - 18 min Variable
    Exhaust setting3 levels (Without exhaust, Fine exahut, Small amount of exhaust)
    Maximum working pressure0.186MPa0.255MPa
    ThermometerDigital display
    5.0℃ - 128.9℃
    Digital display
    5.0℃ - 137.9℃
    Pressure gaugeDigital display 0MPa - 0.3MPa / Analog display 0MPa - 0.4MPa
    Safety devicesPressure safety valve, Over-current and earth leakage breaker, Low water cut off device
    Alarms, error displayLow water heating, Temperature sensor wire disconnection, Over-temperature, Over-cool, Over-pressure,
    Lid abnormality, Abnormality in lid opening / closing lever
    Outside dimensions (W x D x H mm)485 x 470 x 949  547 x 532 x 1046  667 x 652 x 1026667 x 652 x 1206
    Weight (Approximately)44 kg60 kg83 kg89 kg
    Pressure vessel categorySimple pressure vesselSmall sized pressure vessel
    Chamber materialStainless steel (SUS304)
    Power supplyAC110V / 120V / 220V / 230V / 240V,
    50Hz / 60Hz
    (Please specify when ordering.)
    AC220V / 230V / 240V,
    50Hz / 60Hz
              (Please specify when ordering.)          
    Required power supply facility 1.5kW2.0kW3.0kW4.0kW
    Power connection 
    Ring terminal
    Supplied accessories Bottom plate, Drainage hose, Exhaust hose, Exhaust bottle, Drain bottle, Caster stopper (2), Wire mesh basket (2)
    Medical device categoryControlled medicl device, Controlled medical device requiring special maintenance management
    ※Specifications and appearance are subject to change without notice due to continuous product improvement.