up

HOME SERVICE SITE MAP CONTACT US
There are 2 capacities from 420 L to 648 L, for a total of 4 models.
Hot Air Ovens
DON-MⅣ series
DON-MⅣF series

Natural convection type
DON-1000MⅣ
DON-1200MⅣ

Air circulation type
DON-1000MⅣF
DON-1200MⅣF

 ■ Features & Functions
Various models
There are 2 capacities from 420 L to 648 L, for a total of 4 models including a hot air circulation type.
Easy to operate
It can be operated simply turning on the power and setting the operation mode, temperature and time.
Safety is high.
An overheat prevention device, upper limit setting of temperature set value, earth leakage breaker, wire disconnection alarm for heaters and sensors etc. are installed.
Programmed operation of up to 8 steps is possible.
A fixed-value operation, and a programmed operation of up to 8 steps for temperature and time are possible.
Free layout of the chamber space
As the height of the shelf plate can be adjusted freely, the chamber space can be used effectively regardless of the size of materials. Cleaning and maintenance are easy.
 ■ Specifications
          
Product nameHot Air Ovens DON-MⅣ
ModelDON-1000MⅣDON-1200MⅣDON-1000MⅣFDON-1200MⅣF
Inside dimensionsW1000 x D600 x H700 mmW1200 x D600 x H900 mmW1000 x D600 x H700 mmW1200 x D600 x H900 mm
Effective capacity420 L648 L420 L648 L
Convection methodNatural convection methodAir circulation method
TemperatureWorking range100℃ - 260℃50℃ - 260℃
Distribution accuracy±5℃(at 200℃)Without load±4℃(at 200℃)Without load
Operation modeFixed-value operation, Programmed operation (Up to 8 steps)
Timer operation: 1 min - 99 h 59 min
Control method3-digit digital setting, PID control
Number of shelves2, Shelf bracket x 43, Shelf bracket x 62, Shelf bracket x 43, Shelf bracket x 6
Safety devicesAutomatic temperature over-rise prevention function, Independent temperature over-rise prevention device, Detection of heater wire disconnection, Upper limit setting of temperature set value, Over-current and earth leakage breaker, Sensor abnormality detecting function, Thermal relay (only for MⅣF), Fan protection device (only for MⅣF)
Outside dimensionsW1450 x D773 x H1665 mmW1650 x D773 x H1687 mmW1450 x D773 x H1665 mmW1650 x D773 x H1687 mm
Weight (Approximately)160 kg180 kg170 kg190 kg
Chamber materialStainless steel (SUS443J1)
Power supplyAC220V 2.8kW, Single-phase AC220V 3.6kW, Single-phase AC220V 3.0kW, Single-phaseAC220V 3.8kW, Single-phase
※Specifications and appearance are subject to change without notice due to continuous product improvement.