An autoclave equipped with deodorization function that can suppress unpleasant odors and vapors
An autoclave equipped with
deodorization function
HVN series
HVN-50
HVN-85

  • Deodorization function
  • Electro-mechanical lid lock system
  • Dual interlock mechanism
  • Forced cooling unit

  •  ■ Features & Functions
    Deodorization function
    Vapors that cause unpleasant odors and float in the air during heating and unloading are reduced, and furthermore, odors are suppressed with a deodorization filter.

    ※It does not remove the odor of materilas to be sterilized.
    ※Depending on the type of materials to be sterilized, a slight odor may remain.
    Electro-mechanical lid lock system
    The lid can be opened and closed easily and reliably with the one-touch lever.
    A pressure seal method is used as a safety measure.
    Dual interlock mechanism
    The lid is locked by dually detecting the chamber pressure and chamber temperature during operation.
    The lock state is maintained even if an operation is manually interrupted.
     ■ Consumables
    Deodorization filter for HVN
    HVN-50:1set
    HVN-85:2sets
    Forced cooling unit
    After sterilization, the chamber pressure is lowered by fan cooling unit to shorten the time to unloading.
    Memory function
    Set contents can be registered for each mode.
    Required utilities   
    Power supply:Refer to the specifications. Household outlets are not recommended
    ※Ask us for details


     ■ Options for upgrading a system (retrofittable)
    Recorder
    (Analog/Hybrid) Image is an analog recorder.
    ※Class 2 T-type thermocouple included
     ■ Display panel
     ■ Operation cycle of each mode
      MODE 1 : WASTEHeatingSterilizationDeodorization
    Forced Exhaust
      ●Main applications: Sterilization of waste
      MODE 2 : LIQUIDHeatingSterilizationForced Exhaust
      ●Main applications: Sterilization of liquid, which can withstand high temperature and high pressure steam such as water, culture medium, reagent, reagent solution, liquid medicine, etc. and sterilization of instruments made of glass, ceramic, metal or rubber that can withstand high temperature, high pressure steam and rapid pressure reduction during Exhaust.
       
      MODE 3 : LIQUIDHeatingSterilizationNatural cooling
      ●Main applications: Sterilization of liquid, which can withstand high temperature and high pressure steam such as water, culture medium, reagent, reagent solution, liquid medicine, etc. and sterilization of instruments made of glass, ceramic, metal or rubber that can withstand high temperature, high pressure steam and rapid pressure reduction during Exhaust.
     ■ Option
    Stainless steel round wire basket Stainless steel sterilization bucket (without hole) Stainless steel sterilization bucket (with holes) Stainless steel round wire basket
    with solid bottom
    [For HVN-50]
    φ270 x H220(mm)
    φ270 x H270(mm)

    [For HVN-85]
    φ380 x H285(mm)
    [For HVN-50]
    φ270 x H220(mm)
    φ270 x H270(mm)

    [For HVN-85]
    φ390 x H285(mm)
    [For HVN-85]
    φ390 x H375(mm)
    It is recommended to use when using a sterilization bag.
    A large capacity and bucket-shape bottom can prevent the chamber from being contaminated when a sterilization bag is broken.

    [For HVN-50]
    φ270 x H600(mm)

    ※Use a sterilization bag without closing the mouth
                                                         
    Special sterilization bucket for medical waste Detergent for autoclave Sterilization bag
    (Made of aluminum, with handle)br>
    [For HVN-50]
    φ270x520mm
    Detergent to remove cultur media, water scale sticked to the inside of a chamber

    [Standard amount of use]
    1 cap of detergent in 2ℓof water (20cc・1%))
    ※Take out thematerials at the time of use.

    500cc
    Special structure reinforced film.
    Heat resistant temperature is 130℃

    [Type:A] 200pcs
    500x700(mm)

    [Type:B] 200pcs
    620x820(mm)

    ※Use it without closing the mouth.
     ■ Specifications
    Product nameHICLAVE HVN series Autoclaves with deodorization function
    ModelHVN-50HVN-85
    Effective capacity50L85L
    Chamber size (φ x H mm)300 x 710420 x 615
    Operation mode3 modes (WASTE, LIQUID with forced cooling, LIQUID with natural cooling)
    Sterilization temperature setting range105~135℃ Variable
    Lid lock97℃, fixed
    Sterilization time setting range1-250 min, Remaining time is displayed
    Air removal4 min, fixed
    Maximum working pressure0.255MPa
    ThermometerDigital display5~137℃
    Pressure gaugeDigital display 0~0.3MPa / Analog display 0~0.4MPa
    Safety devicesPressure safety valve, Over-current and earth leakage breaker, Low water cut off device
    Alarms, error displayClogging of Exhaust passage, Low water heating, Temperature sensor wire disconnection, Over-temperature, Over-cool, Over-pressure, Abnormality in lid opening/closing lever lock
    Outside dimensions (W x D x H mm)547 x 567 x 1046669 x 687 x 1011
    Weight (Approximately)73 kg88 kg
    Pressure vessel categorySmall sized pressure vessel
    Chamber materialStainless steel (SUS304)
    Power supplyAC 220V, 50/60Hz, Single-phase
    Required power supply facility 2.0kW (10A)3.0kW (15A)
    Power connection
    (Cord length)
     
    Ring terminal (3 m)
    Supplied accessoriesStainless steel wire basket(2), Bottom plate, Drainage hose, Exhaust hose,